A new concept of Power line Communication. Now human operators do the Meter reading for the consumption of Electricity from house to house and building to building. It requires huge number of labor and takes more time to complete the process. Reading error is a common cause of human operator. Automatic Meter Reading (AMR) becomes an executable option to overcome the problems of huge time taking to get the meter readings, the measured values are in kilo watt-hours (kWh) by energy meter. The supply status of the consumer reading unit we identified the disk rotation of the energy meter. The main advantage of this system is a low cost system that produces very encouraging results and it can be implemented upon existing electro-mechanical meters so there is no need to purchasing new meters AMR is the remote collection of consumption data from customer’s utility meters over power line. Power-Line Communication (PLC) carries data on a conductor that is also used simultaneously for AC electric power distribution to consumers. PLC transmitter is responsible for transmission of data from the provider end. At the provider end, there will be the PLC receiver, which is responsible for data receiving, and this module makes an interface with computer, which is responsible for data processing.
Published in | Bioprocess Engineering (Volume 1, Issue 4) |
DOI | 10.11648/j.be.20170104.12 |
Page(s) | 104-109 |
Creative Commons |
This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited. |
Copyright |
Copyright © The Author(s), 2017. Published by Science Publishing Group |
AMR, Carrier Communication, PLC, Power Line
[1] | Amit Jain “A Prepaid Meter Using Mobile Communication” vol3, 2011. |
[2] | Ashna. K, “GSM Based Automatic Energy Meter Reading system with Instant Billing”, 2013. |
[3] | Arun, S “Design And Implementation Of Automatic Meter Reading System Using GSM, ZIGBEE through GPRS”, Vol. no. 2, May2012. |
[4] | Bharat Kulkarni, “GSM based automatic meter reading system using ARM controller”, Volume2, Issue5, Feb 2005. |
[5] | Chunjuanwei, “Implementation Of Automatic Meter Reading System Using PLC and GPRS”, 2011. |
[6] | Elena M, “Power line Communication In Home-Building Automation System”, 2004. |
[7] | Harish P., “GSM Based Automatic Wireless Energy Meter Reading System”, Vol. 1, Issue 9, November – 2012. |
[8] | Moghavvemi. M, “A Reliable and Economically Feasible Automatic Meter Reading System Using Power Line Distribution Network”, Jun 2013. |
[9] | Mejbaul Haque, “Microcontroller Based Single Phase Digital Prepaid Energy Meter for Improved Metering and Billing System”, 2011. |
[10] | Sravanthi. T. “Prepaid Electricity Billing System Using GSM Mobile”, vol. 2, issue 2, Feb 2013. |
[11] | Vivekbhashkar, “A Reliable Automatic Meter Reading System Using Power Line Distribution Network”, issue 3, Vol. No. 1, 2012. |
APA Style
R. Gunasekaran, C. Karthikeyan, J. Pavalam, P. Mohanapriya, A. Preethi, et al. (2017). Power Line Carrier Communication Using Automated Meter Reading. Bioprocess Engineering, 1(4), 104-109. https://doi.org/10.11648/j.be.20170104.12
ACS Style
R. Gunasekaran; C. Karthikeyan; J. Pavalam; P. Mohanapriya; A. Preethi, et al. Power Line Carrier Communication Using Automated Meter Reading. Bioprocess Eng. 2017, 1(4), 104-109. doi: 10.11648/j.be.20170104.12
@article{10.11648/j.be.20170104.12, author = {R. Gunasekaran and C. Karthikeyan and J. Pavalam and P. Mohanapriya and A. Preethi and V. Indhumathi}, title = {Power Line Carrier Communication Using Automated Meter Reading}, journal = {Bioprocess Engineering}, volume = {1}, number = {4}, pages = {104-109}, doi = {10.11648/j.be.20170104.12}, url = {https://doi.org/10.11648/j.be.20170104.12}, eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.be.20170104.12}, abstract = {A new concept of Power line Communication. Now human operators do the Meter reading for the consumption of Electricity from house to house and building to building. It requires huge number of labor and takes more time to complete the process. Reading error is a common cause of human operator. Automatic Meter Reading (AMR) becomes an executable option to overcome the problems of huge time taking to get the meter readings, the measured values are in kilo watt-hours (kWh) by energy meter. The supply status of the consumer reading unit we identified the disk rotation of the energy meter. The main advantage of this system is a low cost system that produces very encouraging results and it can be implemented upon existing electro-mechanical meters so there is no need to purchasing new meters AMR is the remote collection of consumption data from customer’s utility meters over power line. Power-Line Communication (PLC) carries data on a conductor that is also used simultaneously for AC electric power distribution to consumers. PLC transmitter is responsible for transmission of data from the provider end. At the provider end, there will be the PLC receiver, which is responsible for data receiving, and this module makes an interface with computer, which is responsible for data processing.}, year = {2017} }
TY - JOUR T1 - Power Line Carrier Communication Using Automated Meter Reading AU - R. Gunasekaran AU - C. Karthikeyan AU - J. Pavalam AU - P. Mohanapriya AU - A. Preethi AU - V. Indhumathi Y1 - 2017/08/18 PY - 2017 N1 - https://doi.org/10.11648/j.be.20170104.12 DO - 10.11648/j.be.20170104.12 T2 - Bioprocess Engineering JF - Bioprocess Engineering JO - Bioprocess Engineering SP - 104 EP - 109 PB - Science Publishing Group SN - 2578-8701 UR - https://doi.org/10.11648/j.be.20170104.12 AB - A new concept of Power line Communication. Now human operators do the Meter reading for the consumption of Electricity from house to house and building to building. It requires huge number of labor and takes more time to complete the process. Reading error is a common cause of human operator. Automatic Meter Reading (AMR) becomes an executable option to overcome the problems of huge time taking to get the meter readings, the measured values are in kilo watt-hours (kWh) by energy meter. The supply status of the consumer reading unit we identified the disk rotation of the energy meter. The main advantage of this system is a low cost system that produces very encouraging results and it can be implemented upon existing electro-mechanical meters so there is no need to purchasing new meters AMR is the remote collection of consumption data from customer’s utility meters over power line. Power-Line Communication (PLC) carries data on a conductor that is also used simultaneously for AC electric power distribution to consumers. PLC transmitter is responsible for transmission of data from the provider end. At the provider end, there will be the PLC receiver, which is responsible for data receiving, and this module makes an interface with computer, which is responsible for data processing. VL - 1 IS - 4 ER -